HOF Hydraulics Double Vane Pump

HOF Hydraulics Double Vane Pump

HOF Hydraulics Double Vane Pump

HOF Hydraulics Double Vane Pump

HOF V2010 and V2020 With F/P Options

Features

HV2010 and HV2020 series are double pumps for both industrial and mobile application.

The vane pump is not damaged at low speed and high pressure operation because pumping action does not start until the speed is high enough for the vane to throw out. With hydraulically balanced design, the bearing is externally loaded only. Therefore, the pump requires minimized maintenance with long service life.

The inlet or outlet ports can be rotated through increments of 90° in relation to each other, providing application flexibility and easy installation.

With optional flow control and priority valve covers, the pump can be used in more applications. The flow control cover can limit the flow to the primary circuit at the required flow rate, while diverting remaining flow to the tank. The priority valve cover maintains a constant flow to the primary circuit, while diverting remaining flow to the secondary circuit. Each cover comes with a relief valve to limit the maximum pressure of the primary circuit.

100% replacement for Vicker, Rexroth Vane pumps and cartridge kits V10 V20 V10F V20F V20F V20P V210 V230 V20NF V2010 V2010F V2010P V2020 V2020F V2020P

Handling

For maximum service life, the pump should be protected from contamination. Filtering fluid before filling and during operation to maintain or exceed ISO cleanliness code 17/14. Replaceable elements should be changed as per filter supplier instructions.

The drive shaft must align with the power source shaft, avoiding shaft end thrust and applications that impose radial loading.

The start-up procedures should be as follows:

Check the rotation of power source to match the rotation of pump.

Check inlet and outlet ports to ensure all connections are properly installed and check all mounting bolts and flanges to ensure all are tight and properly aligned.

Fill pump with fluid through the outlet port if the pump is mounted above the fluid level. The spline shaft models also need to be lubricated with an anti-fretting grease or similar lubricant.

Place all controls in the neutral position so the pump is unloaded during initial start-up.

Prime the pump within a few seconds when the pump is started.

Bleed off entrapped air from outlet circuit until a steady output flow is observed